How can your UK business cut energy use and bills?

Start with meter data, then tackle unnecessary lighting, heating and equipment running hours before sizing solar or batteries. Government guidance suggests office heating at 19°C, adjusted for your premises and users [S2]. Calculate each measure's avoided energy cost and payback using your own bills, rather than a headline saving percentage. Checked October 2026.

Last checked 17 October 2026

How can you reduce business energy bills without guessing?

Give someone responsibility for an energy log and an action list. Government guidance puts an assessment and simple operating changes ahead of larger investments [S2]. Use our cut energy costs hub to organise the project.

Start with bills, meter readings and opening hours. Kilowatts (kW) measure power; kilowatt-hours (kWh) measure energy consumed over time [S4]. Request half-hourly consumption data and compare working days, closed periods and seasonal patterns. The Carbon Trust recommends using detailed meter data to investigate unexplained use [S1].

Keep energy and price effects separate. Compare consumption per opening hour, occupied room or unit produced. Record weather and changes in activity. A lower bill after a quiet month does not establish an efficiency saving.

Use DESNZ business electricity prices as a benchmark, with its period and tax basis. DESNZ publishes non-domestic fuel price tables; they are not a quotation for your premises [S3]. Calculate avoided expenditure from your own contract’s applicable unit charges.

Which lighting, heating and equipment measures should come first?

Walk the premises while operating and after closing. Check controls before replacing equipment. The Carbon Trust covers lighting, heating, compressed air and factory equipment [S1]; the government SME guide adds a structured approach to assessing opportunities [S4]. The sizing methods below are proposed calculations, not saving rates.

Measure Who it suits How to size the saving Source
Meter review and submetering Sites with unexplained overnight use Identify avoidable load × hours, then confirm by measurement [S1]
LED lighting and occupancy controls Offices, shops and storage areas Difference in measured circuit kW × annual lit hours [S2]
Heating schedules and zoning Pubs, offices and hotels Compare consumption at similar weather and occupancy [S2]
Draught repairs and insulation Frequently heated premises Compare heat demand before and after, allowing for weather [S4]
Compressed-air leak repairs Workshops and production sites Log compressor electricity before and after at equal output [S4]
Motor shutdown and speed control Fans, pumps and conveyors Measure input power across the real duty cycle [S1]
Refrigeration maintenance Food shops, kitchens and cold stores Meter cooling equipment at comparable loading and temperature [S4]

Turn off unnecessary lighting and appliances where safe. Set heating schedules around occupancy and review draughts [S2]. Preserve ventilation, food safety, security and necessary overnight processes. Ask the responsible engineer before changing process temperatures or control settings.

What could an efficiency project save, and when does it pay back?

For an office lighting project, assume the circuit demand falls by 2 kW, electricity costs £0.25/kWh, installed capital is £3,000–£5,000 and extra annual maintenance is £100. These are assumptions: an illustration, not a quote. Low, mid and high cases represent different annual operating hours, not promised performance.

Use case Annual hours Avoided kWh: 2 × hours Annual net benefit: kWh × £0.25 − £100 Simple ROI Payback
Low 1,500 3,000 £650 13–21.7% 4.6–7.7 years
Mid 2,500 5,000 £1,150 23–38.3% 2.6–4.3 years
High 3,500 7,000 £1,650 33–55% 1.8–3 years

Simple return on investment (ROI) = annual net benefit ÷ capital × 100. Payback = capital ÷ annual net benefit. These calculations exclude tax, financing and replacement. Recalculate using measured power and quoted costs. Do not add a control saving to a lighting saving if both remove the same operating hours.

Should solar, batteries and charging follow the efficiency work?

Reassess the remaining demand first. Solar can supply daytime consumption; batteries can shift generation to later use [S5]. Ask for a model using your revised half-hourly load, including export, battery losses and operating costs. Avoid counting the same solar electricity as both avoided imports and export income.

Read solar panels for business and solar and battery cost reduction. Use the commercial solar cost data to prepare questions about installed scope. Our site check can organise roof and energy information.

Charging adds a separate demand and income case. For context, workplace AC (alternating current) charger cost guides indicate £1,400–£2,500 per 7 kW unit. Groundworks, cable runs and connection are extra [S6], [S7].

For a charging illustration, assume two units cost £2,800–£5,000 before those extras. Assume total site use of 1/2/3 sessions daily, 10 kWh per session, 365 days, driver price £0.45/kWh, energy £0.25/kWh and software/maintenance £200 yearly. All operating inputs and shares below are assumptions; no grant is included.

Annual sales = sessions × 10 × 365 × £0.45. Operating net = sessions × 10 × 365 × (£0.45 − £0.25) − £200.

Model Host capital Low / mid / high annual host benefit Simple ROI Payback
fully funded £0 10% of sales: £164 / £329 / £493 Not applicable No host capital
part funded £1,400–£2,500 50% of operating net: £265 / £630 / £995 10.6–18.9% / 25.2–45% / 39.8–71.1% 5.3–9.4 / 2.2–4 / 1.4–2.5 years
self funded £2,800–£5,000 All operating net: £530 / £1,260 / £1,990 10.6–18.9% / 25.2–45% / 39.8–71.1% 5.3–9.4 / 2.2–4 / 1.4–2.5 years

In this illustration the fully funded provider pays operating costs. Part funded splits capital and operating net equally. Add all site extras to host capital before relying on payback. Figures exclude VAT, tax, financing and replacement. Use the charging cost tool to explore energy costs separately.

What should you check before committing money?

Ask for itemised costs, commissioning measurements and a method for tracking results. Identify lease consent, parking loss, supply capacity, planning, insurance, maintenance liability and removal costs in the proposal. Have your solicitor review access rights, agreement length and exit terms before signing.

Separate unit-based savings from fixed charges in your budget. Read standing charges, Climate Change Levy and electricity contracts. For relief eligibility, use our energy grants guide and check with your accountant.

What is your next step?

Gather your consumption profile, opening hours, tenure and priority measures. Then get matched with an installer that covers your area.

Piggy Pineapple Ltd operates this referral service. We refer enquiries to installer partners and may be paid a fee. Our owner holds shares in at least one partner. Before sharing your details, we name the proposed partner and disclose whether our owner holds shares in it. See how we work.

Common questions

Does a smart meter reduce consumption by itself?

It supplies readings and usage information. You still need to change equipment or operating hours. Ask for access to the data and nominate someone to review it [S2].

Should every room have the same heating setting?

Review zones separately. Activity, occupancy and solar gain differ between rooms; the Carbon Trust recommends matching heating to the use of each area rather than one setting throughout [S1].

When should a business consider higher-efficiency motors?

Start with motors that run for long hours. Log their load and operating time, then assess replacement and speed control against the actual process requirement [S1].

Can refrigeration be included in a switch-off checklist?

Keep essential cooling operating. Inspect door seals, condenser cleanliness and temperature controls instead; the government SME guide covers refrigeration measures without abandoning its purpose [S4].

How should variable-speed drives be assessed?

Measure the pump or fan load at different operating conditions and ask an engineer whether speed control suits the process. Compare measured electricity consumption before and after the change [S1].

Ask about your site

Free for site owners. No obligation. We name the installer partner before we pass on any details.

Read our privacy notice

Sources

  1. Better business guide to energy saving, Carbon Trust,Last checked 17 October 2026
  2. Energy advice for businesses, UK Government,Last checked 17 October 2026
  3. Gas and electricity prices in the non-domestic sector, Department for Energy Security and Net Zero,Last checked 17 October 2026
  4. SME energy efficiency guide, Department of Energy and Climate Change,Last checked 17 October 2026
  5. Solar roadmap, Department for Energy Security and Net Zero,Last checked 17 October 2026
  6. EV charger installation cost UK 2026, Installation cost guide,Last checked 17 October 2026
  7. Commercial EV charger installation cost, Installation cost guide,Last checked 17 October 2026
Check your site