What should a fire risk assessment for EV charging cover?
Review your premises fire risk assessment before fixing the charger layout. Government guidance describes 5 assessment steps, from identifying hazards to regular review [S1]. Include people, escape routes, electrical equipment and operating arrangements. Covered parking needs particular attention, and England guidance does not replace devolved requirements. Use competent help where needed. Checked October 2026.
Do EV chargers need a fire risk assessment at your business?
Treat charging as a proposed change to your premises, then ask how it affects the existing assessment. GOV.UK requires the responsible person to assess and regularly review fire risks and keep a written record [S1]. Start before the parking layout becomes an installation contract: moving a drawing is easier than moving installed equipment.
Prepare a plan showing the charging bays, buildings, escape routes, gates and storage areas. Add the operating hours and describe who uses the site. Ask the assessor to review the proposal against the rest of your business, rather than looking only at the charging unit.
This guide helps you commission and organise that review. It does not certify a design. Keep unresolved questions on an action list, with an owner and a completion record. Read the covered parking guide if your bays sit beneath a roof or building.
Who should carry out an EV charging risk assessment?
GOV.UK identifies employers, owners, landlords, occupiers and others controlling premises as possible responsible persons. People sharing responsibilities must cooperate [S4]. Bring your property manager, electrical designer, installer and fire assessor into the same review. Ask your solicitor to check responsibility boundaries in a lease or operating agreement.
When commissioning an assessor, request evidence of experience with your premises type and the proposed charging arrangement. Ask what they will inspect, what documents they need and what the report excludes. Include follow-up review of the installed layout in the scope, so unresolved design assumptions do not disappear at handover.
For Scotland, the fire service explains that using external assistance leaves the dutyholder accountable [S5]. In Northern Ireland, start with the NIFRS guide matching your premises [S6]. England’s covered-parking publication explicitly applies to England [S2]; ask your assessor to identify the applicable national requirements rather than copying an English checklist into a different jurisdiction.
What should an EV charger risk assessment examine?
Use the government’s sequence: identify hazards and people, evaluate and reduce risk, record findings and emergency arrangements, then review [S1]. For your project, turn that sequence into specific questions on a marked-up site drawing.
| Bring to the assessor | Ask them to examine | Keep in the project file |
|---|---|---|
| Parking and building plan | People, escape routes and nearby activities | Reviewed layout |
| Electrical design | Fault protection and isolation arrangements | Design evidence |
| Storage and delivery plan | Interaction with other site hazards | Agreed controls |
| Opening and staffing hours | Response when the office is closed | Operating instructions |
| Existing fire strategy | Changes needed for the proposal | Updated assessment |
Include people who may need help leaving, visiting drivers and contractors unfamiliar with the premises. Ask how the arrangement works during deliveries or when parking is full. These are suggested commissioning questions, not a universal engineering specification.
Use the charger positioning guide to prepare options. Ask the assessor and installer to resolve any conflict between a convenient cable route, accessible use and safe circulation before choosing the final position.
Which fire safety measures are relevant to EV charging?
The technical covered-parking guidance discusses detection, suppression, smoke management, separation, access, water supplies and run-off. It organises possible measures through eliminating, reducing, isolating and controlling risks [S3]. The right combination needs a competent assessment of your building and operating conditions.
Request the reasoning behind each proposed measure. Have the design team identify what is included in the charger quotation and what belongs to a separate building project. Ask for commissioning evidence and ongoing inspection costs. Avoid treating a list of possible measures as an automatic shopping list for every outdoor car park.
If a stationary battery is proposed, give its location and specification to the assessor as well. Keep that review connected to the battery fire safety guide. A charger-only scope should not quietly become approval for an added storage installation.
What should staff do if charging equipment develops a fault?
Agree a written defect-reporting and emergency procedure with your specialists. Government evacuation guidance addresses escape routes, suitable exits, training and arrangements for people needing assistance [S8]. Match the charging instructions to that premises-wide plan.
Ask the installer to identify isolation arrangements and explain who is authorised to operate them. Have staff instructions distinguish a routine equipment defect from an emergency. Do not build a response plan around untrained staff attempting battery firefighting or moving a burning vehicle. Ask the assessor to specify the information responders need and where it will be available.
For routine operation, HSE describes electrical maintenance as necessary to prevent danger, with its form depending on use and environment [S7]. Agree visual checks, specialist inspections, fault escalation and records. Include responsibilities for damaged cables and equipment struck by vehicles in the service discussion. The maintenance guide can help you frame that request.
When should the assessment be reviewed after installation?
Keep regular review in your management calendar [S1]. Also ask the assessor to define change triggers for your site: moving bays, changing access hours, adding equipment or altering nearby activities. Scotland’s guidance specifically identifies significant premises or process changes as review reasons [S5].
Before opening, compare the installed arrangement with the reviewed drawing. Record remaining actions and who authorises use. Under fully funded, part funded and self funded arrangements, request the same clear operating handover. Equipment ownership is not a substitute for knowing who reports a defect, arranges maintenance or controls the premises.
What should you do next?
Send your layout, current assessment and proposed operating pattern to the assessor before accepting the final design. Request a written action list and include its costs in the project decision.
Piggy Pineapple Ltd operates this referral service. We refer enquiries to installer partners and may be paid a fee. Our owner holds shares in at least one partner. Before sharing your details, we name the partner and disclose any shareholding our owner holds in it. Read how we work and get matched with an installer that covers your area.
Common questions
Can the fire service write the assessment for your business?
GOV.UK says your local fire and rescue authority may advise, but cannot carry out the assessment for you. Appoint competent help if you lack time or expertise [S1].
Does an open-sided parking deck count as covered parking?
The technical guidance includes both enclosed and open-sided covered car parks. Ask the assessor to classify your actual structure before choosing the review scope [S3].
Does a grant or planning approval establish fire safety?
The covered-parking guidance does not replace safety regulations. Keep the fire assessment and evidence of its actions alongside other approvals; an approval alone does not answer the assessment questions [S2].
Is annual portable appliance testing the rule for every charger?
HSE says maintenance depends on the equipment, environment and use; it does not prescribe annual portable appliance testing for all equipment. Request a suitable charger inspection and maintenance schedule [S7].
Can a template replace a site visit and assessment?
A template can organise the record, but the assessment still needs to identify your hazards, people and controls. NIFRS offers premises-specific guides and templates as starting points [S6].
Ask about your site
Sources
- Fire risk assessments, GOV.UK,Last checked 16 October 2026
- Covered car parks fire safety guidance, OZEV,Last checked 16 October 2026
- Covered car parks technical guidance, OZEV,Last checked 16 October 2026
- Fire safety responsibilities, GOV.UK,Last checked 16 October 2026
- Fire risk assessment in Scotland, Scottish Fire and Rescue Service,Last checked 16 October 2026
- Fire safety guides, Northern Ireland Fire and Rescue Service,Last checked 16 October 2026
- Maintaining electrical equipment safety, HSE,Last checked 16 October 2026
- Fire safety and evacuation plans, GOV.UK,Last checked 16 October 2026